Parameters/Test conditions

Min

Typ.

Max

Unit

Note

1

Signal Operating Wavelength

1000

1064

1100

nm


2

Pump Operating Wavelength

800


1000

nm


3

 

Pump Fiber

Core Diameter


105


µm

Refer to fiber codes

 

4


Cladding Diameter


125


µm


5


Numerical Aperture

0.15

-


6

Signal Fiber

HI1060 or 6/125 DCF

Refer to fiber codes


Pump Efficiency (%)

Signal Insertion Loss (dB)

Power Handling (W, each port)

 

 

 

7

 

 

 

Output

Fiber

6/125 DCF

>90Typ.93

<0.7Typ. 0.5

25



10/125 DCF

>90Typ. 93

<0.7Typ. 0.5

25



12/125 DCF

>90Typ. 93

<0.7Typ. 0.5

25



15/125 DCF

>90Typ. 93

<0.7Typ. 0.5

25



20/125 DCF

>90Typ. 93

<0.7Typ. 0.5

25



20/200 DCF

>95Typ. 97

<0.7Typ. 0.5

50



25/250 DCF

>95Typ. 97

<0.7Typ. 0.5

50



30/250 DCF

>95Typ. 97

<0.7Typ. 0.5

50



20/400 DCF

>95Typ. 97

<0.7Typ. 0.5

50

8



1.3

-


9

Optical Isolation

20



dB


10

Fiber Length

0.8



m

Each port

11

Operating Environment Temperature

-5


+70


12

Operating Humidity

5


95

%RH

Not recommend in high

humidity for long time.

13

Storage Temperature

-40


+85


14

Package

C1, C2, C4, C7

-

Handling power is

different with PKG