Integrated low-profile XY linear motor stage
Nanometer-level performance in a large travel format
High resolution (1 nm), repeatability (75 nm), and accuracy (250 nm)
In-position stability of <1 nm
Anti-creep crossed-roller bearings
High dynamic performance with direct-drive technology
ULTRA performance grade option
The ANT130XY series stages offer nanometer-level performance in XY travels up to 160 mm. The integrated, sleek design provides an extremely low profile of only 85 mm. The stage comes with proprietary direct-drive motor technology, noncontact linear encoders, limits, integrated cable management system, and three performance grades.
The ANT130XY design allows critical elements such as orthogonality, straightness, and flatness to be optimized, resulting in a stage with exceptional geometric tolerances. Aerotech’s direct-drive technology has no hysteresis or backlash, enabling accurate and repeatable nanometer-scale motion in both the X and Y dimensions. All travel options (60 mm x 60 mm, 110 mm x 110 mm, 160 mm x 160 mm) come with the 85 mm profile height. The integrated cable management system is designed for long life and to minimize drag forces.
Only noncontact direct-drive technology offers the robust, accurate, and high-speed positioning necessary for mass production of precision devices. ANT130XY stages utilize advanced direct-drive technology pioneered by Aerotech to achieve the highest level of positioning performance. This direct-drive technology is high-performance, non-cogging, noncontact, high speed, high resolution, and high accuracy. This unique drive and bearing combination, packaged in an extremely small-profile and footprint, offers tangible advantages in many applications such as high-precision positioning, disk-drive fabrication, fiber alignment, optical delay element actuation, sensor testing, and scanning processes that demand smooth and precise motion.
The ANT130XY can be combined with other Aerotech ANT series products (vertical lift stages, direct-drive rotaries, and goniometers) to create unique, high performance, multi-axis systems.
In order to achieve the highest possible system accuracy from our multi-axis nanopositioning systems, Aerotech has developed an advanced, dynamic trajectory calibration system. To take advantage of this sophisticated calibration system, the mechanical system has to be completely assembled, functionally tested, and calibrated in our best-in-class metrology labs. Nanometer-level system accuracy can only be achieved under stringent environmental conditions, calibrating with the best test equipment, using the highest-precision mechanical elements, and utilizing the ULTRA software capabilities of Aerotech’s industry-leading controls. By implementing ULTRA dynamic trajectory calibration with the ANT130XY, we are able to produce guaranteed two-dimensional accuracies of ±250 nm or better.
The plots provided in the specifications illustrate performance differences between a standard ANT130XY and the ULTRA version. Straightness errors, orthogonality errors, and accuracy errors caused by stage yawing are virtually eliminated.
-PLUS and-ULTRA require the use of an Aerotech controller. Specifications for -BASE and -PLUS options are per axis measured 25 mm above the tabletop. Specifications for -ULTRA are XY measured 25 mm above the tabletop. Certified with each stage. Requires the selection of an appropriate amplifier with sufficient voltage and current. In-position jitter listing is 3 sigma value Axis orientation for on-axis loading is listed. -PLUS and -ULTRA require the use of an Aerotech controller. Specifications for -BASE and -PLUS options are per axis measured 25 mm above the tabletop. Specifications for -ULTRA are XY measured 25 mm above the tabletop. Certified with each stage. Requires the selection of an appropriate amplifier with sufficient voltage and current. In-position jitter listing is 3 sigma value. Axis orientation for on-axis loading is listed. -PLUS and -ULTRA require the use of an Aerotech controller. Specifications for -BASE and -PLUS options are per axis measured 25 mm above the tabletop. Specifications for -ULTRA are XY measured 25 mm above the tabletop. Certified with each stage. Requires the selection of an appropriate amplifier with sufficient voltage and current. In-position jitter listing is 3 sigma value. Axis orientation for on-axis loading is listed. Note: Linear amplifiers are required to achieve the listed specifications. Other options are available. Note: To ensure the achievement and repeatability of specifications over an extended period of time, environmental temperature must be controlled to within 0.25°C/24 hours. If this is not possible, alternate products are available. Please consult Aerotech Application Engineering for more information. Note: -CN1 option not valid for systems using bus voltages greater than 80 VSpecifications
Mechanical Specifications
ANT130XY-060 Base PLUS(1,2) ULTRA(1,2) Travel 60 mm Accuracy(2,3) ±2.5 µm ±250 nm ±250 nm Resolution (Minimum Incremental Motion) 1 nm Repeatability (Bidirectional)(3) ±100 nm ±75 nm ±75 nm Repeatability (Unidirectional) ±25 nm ±25 nm ±25 nm Straightness(3) ±1.5 µm ±1.5 µm ±250 nm Flatness(3) ±1.5 µm ±1.5 µm ±1.0 µm Pitch 49 µrad (10 arc sec) 49 µrad(10 arc sec) 49 µrad (10 arc sec) Roll 49 µrad (10 arc sec) 49 µrad (10 arc sec) 49 µrad (10 arc sec) Yaw 24 µrad (5 arc sec) 24 µrad (5 arc sec) 24 µrad (5 arc sec) Orthogonality 49 µrad (10 arc sec) 15 µrad (3 arc sec) 4.8 µrad (1 arc sec) Maximum Speed(4) 350 mm/s (Upper Axis) Maximum Acceleration(4) 1 g - 10 m/s2 (No Load) (Upper Axis) Speed Stability See graph for typical performance Settling Time See graph for typical performance In-Position Stability(5) <1 nm Maximum Force (Continuous) 23 N Load Capacity(6) Horizontal 12.0 kg Moving Mass Upper 1.5 kg Lower 4.2 kg Stage Mass 5.5 kg Material Aluminum Body/Black Hardcoat Finish MTBF (Mean Time Between Failure) 30,000 Hours ANT130XY-110 Base PLUS(1,2) ULTRA(1,2) Travel 110 mm Accuracy(2,3) ±4.0 µm ±300 nm ±300 nm Resolution (Minimum Incremental Motion) 1 nm Repeatability (Bidirectional)(3) ±100 nm ±75 nm ±75 nm Repeatability (Unidirectional) ±25 nm ±25 nm ±25 nm Straightness(3) ±1.5 µm ±1.5 µm ±300 nm Flatness(3) ±1.5 µm ±1.5 µm ±1.0 µm Pitch 58 µrad (12 arc sec) 58 µrad (12 arc sec) 58 µrad (12 arc sec) Roll 58 µrad (12 arc sec) 58 µrad (12 arc sec) 58 µrad (12 arc sec) Yaw 29 µrad (6 arc sec) 29 µrad (6 arc sec) 29 µrad (6 arc sec) Orthogonality 49 µrad (10 arc sec) 15 µrad (3 arc sec) 2.4 µrad (0.5 arc sec) Maximum Speed(4) 350 mm/s (Upper Axis) Maximum Acceleration(4) 1 g - 10 m/s2 (No Load) (Upper Axis) Speed Stability See graph for typical performance Settling Time See graph for typical performance In-Position Stability(5) <1 nm Maximum Force (Continuous) 23 N Load Capacity(6) Horizontal 12.0 kg Moving Mass Upper 2.1 kg Lower 5.7 kg Stage Mass 7.4 kg Material Aluminum Body/Black Hardcoat Finish MTBF (Mean Time Between Failure) 30,000 Hours ANT130XY-160 Base PLUS(1,2) ULTRA(1,2) Travel 160 mm Accuracy(2,3) ±5.0 µm ±300 nm ±300 nm Resolution (Minimum Incremental Motion) 1 nm Repeatability (Bidirectional)(3) ±100 nm ±75 nm ±75 nm Repeatability (Unidirectional) ±25 nm ±25 nm ±25 nm Straightness(3) ±2.0 µm ±2.0 µm ±300 nm Flatness(3) ±2.0 µm ±2.0 µm ±1.0 µm Pitch 73 µrad (15 arc sec) 73 µrad (15 arc sec) 58 µrad (12 arc sec) Roll 73 µrad (15 arc sec) 73 µrad (15 arc sec) 58 µrad (12 arc sec) Yaw 39 µrad (8 arc sec) 39 µrad (8 arc sec) 29 µrad (6 arc sec) Orthogonality 49 µrad(10 arc sec) 15 µrad (3 arc sec) 2.4 µrad (0.5 arc sec) Maximum Speed(4) 350 mm/s (Upper Axis) Maximum Acceleration(4) 1 g - 10 m/s2 (No Load)(Upper Axis) Speed Stability See graph for typical performance Settling Time See graph for typical performance In-Position Stability(5) <1 nm Maximum Force (Continuous) 23 N Load Capacity(6) Horizontal 12.0 kg Moving Mass Upper 2.4 kg Lower 6.9 kg Stage Mass 8.9 kg Material Aluminum Body/Black Hardcoat Finish MTBF (Mean Time Between Failure) 30,000 Hours Electrical Specifications
Drive System Brushless Linear Servomotor Feedback Noncontact Linear Encoder Maximum Bus Voltage 320 VDC (-4DU-25DU), 80 VDC (-25DU) Limit Switches 5 V, Normally Closed Home Switch Near Center Recommended Controller
Multi-Axis A3200 Npaq MXR
Npaq MR-MXH
Ndrive ML-MXHEnsemble Epaq MXH
Epaq MR-MXH
Ensemble ML-MXH
Ensemble LABSingle Axis Soloist Soloist ML-MXH Dimensions
Enlarge Image
Enlarge Image
Enlarge Image
Ordering Information
ANT130XY Two-Axis XY Direct-Drive Nanopositioning Stage
Travel (Required)Option Description -060 60 mm travel -110 110 mm travel -160 160 mm travel Connectors (Required)
Option Description -CN1 Single 25-pin D connector, 25DU -CN2 Two connectors, 4-pin HPD and 25-pin D, 4DU-25DU Cable Managment (Required)
Option Description -CMS2 Post for two-axis cable support -CMS3 Post for three-axis cable support Mounting Plate (Optional)
Option Description -MP Mounting plate Performance Grade (Required)
Option Description -PL1 Base performance -PL3 High-accuracy performance, PLUS -PL4 Ultra high-accuracy performance, ULTRA Integration (Required)
Aerotech offers both standard and custom integration services to help you get your system fully operational as quickly as possible. The following standard integration options are available for this system. Please consult Aerotech if you are unsure what level of integration is required, or if you desire custom integration support with your system. -TAS Integration - Test as system
Testing, integration, and documentation of a group of components as a complete system that will be used together (ex: drive, controller, and stage). This includes parameter file generation, system tuning, and documentation of the system configuration.-TAC Integration - Test as components
Testing and integration of individual items as discrete components that ship together. This is typically used for spare parts, replacement parts, or items that will not be used together. These components may or may not be part of a larger system.